VHP Sterilization Pass Box/Transfer Window
Brief introduction
Product Feature
Uni-Directional Air Flow,VHP Sterilizing,Air Velocity and VHP Concentration Monitor
For Product/Material Cross ZONE Transfer (Class B/C/D to A)
One side Maintenance, Double side Operation, Interlock Door, Customized size
Uni-Directional Air Flow,VHP Sterilizing,Air Velocity and VHP Concentration Monitor
For Product/Material Cross ZONE Transfer (Class B/C/D to A)
One side Maintenance, Double side Operation, Interlock Door, Customized size
Description
Customer Case
Featured Products
VHP PASSBOX
Product Feature
Uni-Directional Air Flow,VHP Sterilizing,Air Velocity and VHP Concentration Monitor
For Product/Material Cross ZONE Transfer (Class B/C/D to A)
One side Maintenance, Double side Operation, Interlock Door, Customized size
Design Feature
316L SS Chamber+ Tempered Glass
Double Door Inter-Locked
SIEMENS PLC, Print/Record/Storage and Traceable Data
≥LOG6 De-Pyrogen
Comply GAMP5/EU-GMP/FDA Guideline
Specification
If you are interested in this, please contact me: Nana Zhang
Cell Phone: 0086-15800947006
https://medigrade.en.made-in-china.com/ made-in-china.com
Product Feature
Uni-Directional Air Flow,VHP Sterilizing,Air Velocity and VHP Concentration Monitor
For Product/Material Cross ZONE Transfer (Class B/C/D to A)
One side Maintenance, Double side Operation, Interlock Door, Customized size
Design Feature
316L SS Chamber+ Tempered Glass
Double Door Inter-Locked
SIEMENS PLC, Print/Record/Storage and Traceable Data
≥LOG6 De-Pyrogen
Comply GAMP5/EU-GMP/FDA Guideline
Specification
Parameter | Description |
Clean grade for working area | Class A |
Falling air velocity | 0.36--0.54m/s ,adjustable |
Cabin sealing | Under the pressure of 500Pa, the leakage rate of the cabin is not more than 5% within 10min; |
Pressure difference | -100--+100Pa can be adjusted, keep 20--60Pa during aseptic operation, maintain the pressure under static conditions to a set value |
of not less than 10Pa | |
Airflow pattern | Single way |
Automatic removal efficiency | Concentration< 1ppm |
Sterilization concentration curve range | 0-1000PPM |
Power | AC220V±22V 50Hz±1Hz |
Consumption | 0.4kw |
Size | Inner size W650*D600*H600,Outer size W850*D700*H2000customized |
Verification content | Sterilization efficiency: biological indicator, chemical test paperClass A laminar flow: wind speed, differential pressure, dust particles, floating bacteria |